Vibration Analyzer

www.thermoscan.co.th

Thermoscan Co., Ltd  

HOME
VIBRATION ANALYZER
VIBRATION SERVICES
VIBRATION PRODUCT
VIBRATION CONTACT


Why is Monitoring Vibration Important?
Why Monitor Machine Vibration?
VIBRATION PRODUCT : vb5 | vb6 | vb7| vb Online| Ranger Sensor| Ranger Booster| Ranger Station | Ranger Bridgevibration vb5

The new standard for online machine surveillance

The vbOnline™ system provides 24/7 round the clock surveillance of your critical assets. It is a flexible, modular system that is constantly and automatically evaluating machine operating condition, instantly notifying you when potential problems arise, thus avoiding costly downtime. The vbOnline system allows you to collect data more cost effectively, more timely, and with improved accuracy compared with walk around portable routines. You can safely monitor machines in dangerous and inaccessible environments. vibration vb5
Specifications : MODEL vbOnline : Remarks :
Analog Inputs
Number of channels
4 to 32
Configuration in blocks of 4
Simultaneous recordings Dual channel Any odd #channel with any
even #channel
Channel scan rate ≤8s per channel pair Accel 1000 Hz 400 lines
Compatible sensors Accel, vel, displ, voltage o/p,
4-20 mA
 
DC-coupled ranges 0 V to 20 V, -10 V to 10 V,
-20 V to 0 V
Selectable to suit sensor type
AC-coupled ranges 16 V peak-peak Allows for ± 8 V sensor
output swing
Sensor drive current

4 mA @ 24 V Enable for ICP®type sensors
A to D conversion 24 bits  
Input impedance >100 kΩ  
Analog Measurements  
Measurement types Single value, time waveform,
spectrum
 
Quantities Accel, vel, displ, demod,
user-scaled
User scaling for voltage and
4-20 mA sensors
Max value (Accelerometer) ± 80 g, ± 100 mm/s (4 in/s),
± 10 mm (0.4 in)
with 100 mV/g sensor
Max value (Vel. sensor) ± 2000 mm/s (80 in/s) with 100 mV/in/s sensor
Max value (Displ sensor) ± 2 mm (80 mil) with 100 mV/mil sensor
Spectrum Fmax values 100 Hz to 40 kHz (6000 CPM
to 2400 kCPM)
In 23 steps
Sampling rates 256 Hz to 102.4 kHz In 23 steps
Dynamic range ≥95 dB  
Harmonic distortion Less than -70 dB typica Other distortions and noise
are lower
Accuracy ± 1% (0.1 dB) For DC level and AC
measured at 100 Hz
AC Frequency response ± 0.1 dB from 10 Hz to 15 kHz;

± 3 dB from 1 Hz to 40 kHz
From value measured at
100 Hz
High freq response also
applies to DC ranges
Accel and velocity
Signal Processing
Number of spectral lines 400, 800, 1600, 3200, 6400 3200 lines (8192 samples)
max for dual channel
recordings
Time waveform samples 1024, 2048, 4096, 8192, 16384  
Window types Hanning, rectangular  
Averaging types Linear, exponential, peak
hold, synchronous
 
Number of averages 1, 2, 4, 8, 16, 32, 64, 128  
Overlap 0, 12.5, 25, 37.5, 50, 62.5,
75, 87.5%
 
Demodulation bandwidths 20 bandwidth options From 125 to 1250 Hz up to 16
to 20 kHz
Quickscan
Scan rate 2 seconds per channel pair For DC-coupled sensors, no
integration (e.g. prox probes)þ
Measurement type 5 seconds per channel pair
Average DC value or 10 Hz to
1 kHz overall
For other sensor types
Accelerometer readings are
converted to velocity
Tachometer Inputs
Tachometer Inputs 4 Multiplexed
Range 0.5 Hz to 5000 Hz
(30 to 300 000) RPM
Divided by number of pulses
per revolution
Recommended sensor Hall effect Also optical, laser and
Keyphasor® tach sensors
Power supply to sensor 12 V Current limited by a
50 mA PTC
Input type Optically isolated,
accepts TTL
 
TTL inputs pulses 2.5 V (2 mA) min, 12 V (20 mA)
max, off-state ‹0.8 V
 
Relay Outputs
Number 4  
Type SPST, normally open  
Voltage and current rating 250 V AC or 30 V DC, 5 A  
Controlled by Server User configurable, based on
alarms
Status Indicators
System status 2 x LEDs One for power, one for
DSP status
Vibration status 4 sets LEDs: red,
yellow, green
Indicates alarm state, user
configurable
Relay status 4 x LEDs Indicates if each relay is
energized
Comms and Power
Network comms Ethernet v2.0, IEEE 802.3,
TCP/IP, 10/100baseT,
Auto senses 10/100 Mbps and
half/full duplex
Network connection,
link speed
RJ45 socket  256 kbps
(optimum), 2400 bps (min)
Via any commercially
available link
Diagnostic comms RS232 @ 230 kbaud,
RJ12 socket
Auto-baud at power up 57.6
to 230 kbaud
Power supply 250 mA @ 9 V to 36 V DC  
Mechanical
Mounting Standard 35 mm DIN rail For installation in enclosed
control cabinet
Size 308 mm x 130 mm x 45 mm (60 mm including DIN rail)
Optional sealed housing IP 65 / NEMA 4  
Environmental
Temperature range -10 °C to 60 °C (14 to 140) °F  
Humidity 95% RH non-condensing  
EMC EN61326 Emissions and immunity
Analysis Software
Name Ascent Level 3  
Compatible portables vbSeries®  
Thermoscan Co., Ltd. (บริษัท เทอร์โมสแกน จำกัด)
www.thermoscan.co.th

©Copyright 2012 - Thermoscan Co., Ltd. - All Rights Reserved.

  731 PM Tower, 5th Floor, Asok Dindaeng Road, Dindaeng, Dindaeng,
  Bangkok 10400   
Tel: (02) 642-9489    Fax: (02) 642-9424
  E-mail: tms@thermoscan.co.th