Vibration Analyzer

www.thermoscan.co.th

Thermoscan Co., Ltd  

HOME
VIBRATION ANALYZER
VIBRATION SERVICES
VIBRATION PRODUCT
VIBRATION CONTACT


Why is Monitoring Vibration Important?
Why Monitor Machine Vibration?
VIBRATION PRODUCT : vb5 | vb6 | vb7| vb Online| Ranger Sensor| Ranger Booster| Ranger Station | Ranger Bridgevibration

Ranger Sensor™ Module


Wireless Ranger Sensor modules are mounted on the machinery components being monitored. These compact yet rugged sensors'hibernate' until a scheduled vibration or temperature recording is requessssted by the OnlineManager™ software.

Using the 'Wake on High Vibration' feature, these sensors can also be programmed to wake automatically and take an immediate measurement if a user-configured vibration level is exceeded.

Once a measurement has been taken and transmitted, the sensors then return to their previous sleep state until required again. With recommended usage, sensor battery life can exceed 18 months.
Specifications : Ranger System : Remarks :
Performance
Sensing elements PZT ceramic Shear mode piezo
Axes Biaxial Vertical (Z) and Horizontal (X)
Frequency response (+/- 3 dB) 3 Hz to 10 kHz 6 kHz X axis
Measurement dynamic range ± 50 g peak  
Sample rate 1024 Hz to 51.2 kHz 16 options. Fmax range in Ascent software 400 Hz to 20 kHz
Waveform number of samples 1024, 2048, 4096, 8192 FFT resolution in Ascent 400, 800, 1600, 3200 lines
Max recording duration 4 seconds approx.  
Analog to digital conversion 24-bit ≥ 95 dB dynamic range
Demodulation 2 kHz to 10 kHz bandwidth On Z axis
Wake on High Vibration (WoHV) 2 mm/s to 20 mm/s RMS In 10 to 1000 Hz band, Z axis
Temperature accuracy ± 2 °C Internal temperature, -10 °C to 80 °C
Electrical
Power supply Lithium Thionyl Chloride, 1/6D cell Non-rechargeable, user-replaceable primary cell
Voltage and capacity 3.6 V, 1.7 Ah  
Battery life 18 months At typical usage*
Electrical noise – broadband 300 μg RMS  
Electrical noise – spectral 10 Hz 35 μg/√Hz RMS  
Electrical noise – spectral 100 Hz 20 μg/√Hz RMS  
Electrical noise – spectral 1 kHz 5 μg/√Hz RMS  
Mechanical
Case material 316L stainless steel Glass reinforced polyacetal for battery cover
Mounting 1/4"-28 UNF thread Optional cementing pads (37 mm diameter)
Size 42 mm x 46 mm Diameter x height
Weight 175 g  
Environmental
Temp range -10 °C to 80 °C (14 °F to 176 °F) Extreme temperatures reduce optimum battery life
Ruggedness 1.2 m drop onto concrete  
Sealing – sensor and electronics Epoxy potted  
Sealing – battery compartment IP67 O-ring seal

Notes: *Typical usage is defined as Wake on High Vibration armed, six sets of dual channel recordings each day (Velocity, 1kHz, 800 lines). Temperature 25°C.

Thermoscan Co., Ltd. (บริษัท เทอร์โมสแกน จำกัด)
www.thermoscan.co.th

©Copyright 2012 - Thermoscan Co., Ltd. - All Rights Reserved.

  731 PM Tower, 5th Floor, Asok Dindaeng Road, Dindaeng, Dindaeng,
  Bangkok 10400   
Tel: (02) 642-9489    Fax: (02) 642-9424