FLIR P660 Technical Specifications |
Imaging Performance |
Field of view/min focus distance |
12° X 9° / 1.2 m |
Spatial resolution (IFOV) |
0.33 mrad |
Thermal sensitivity @ 50/60Hz |
30 mK @ +30°C |
Image frequency |
30 Hz |
Electronic Zoom |
1–8X continuous, digital zoom, including panning |
Focus |
Automatic or manual (electric or on the lens) |
Digital image enhancement |
Normal and enhanced |
IR resolution |
640 X 480 pixels |
Focal Plane Array (FPA) / Spectral range |
Uncooled microbolometer / 7.5–13 µm |
Imaging Performance |
Display |
Built-in widescreen, 5.6 in. LCD, 1024 X 600 pixels |
Viewfinder |
Built-in, tiltable LCD, 800 X 600 pixels |
Automatic image adjustment |
Continuous / manual; linear or histogram based |
Manual image adjustment |
Level/span / max / min |
Contrast optimization |
Automatic, adjustable DDE |
Image modes |
IR-image, visual image, thumbnail gallery |
Reference image |
Shown together with live IR image |
Measurement |
Temperature ranges |
–40°C to +500°C |
Accuracy (% of reading) |
±1°C or ±1% of reading for limited temperature range,
±2°C or ±2% of reading |
Measurement analysis |
Spotmeter |
10 |
Area |
5 boxes or circles with max. / min. / average |
Automatic hot / cold detection |
Max / Min temp. value and position shown within box, circle or on a line |
Isotherm |
2 with above / below / interval |
Profile |
1 live line (horizontal or vertical) |
Difference temperature |
Delta temperature between measurement functions or reference
temperature |
Reference temperature |
Manually set or captured from any measurement function |
Emissivity correction |
Variable from 0.01 to 1.0 or selected from editable materials list |
Measurement corrections |
Reflected temperature, optics transmission, atmospheric transmission
and external optics |
Measurement function alarm |
Audible/visual alarms (above / below) on any selected measurement
function |
Set-up |
Set-up commands |
Configurable measurement tools menu; configure information to
be shown in image; 2 Programmable buttons; user profiles; local
adaptation of units, language, date and time formats |
Storage of images |
Image storage |
Standard JPEG, including measurement data, on memory card
Built-in RAM for burst recording |
Image storage mode |
IR / visual images; simultaneous storage of IR and visual images
Visual image is automatically associated with corresponding IR image |
Periodic image storage |
Every 10 seconds up to 24 hours |
Panorama |
For creating panorama images in FLIR Reporter Building software |
Image annotations |
Voice |
60 seconds stored with the image |
Text |
Predefined text or free text from PDA (via IrDA) stored with the image |
Image marker |
4 on IR or visual image |
GPS |
Location data automatically added to every image from built-in GPS |
Video recording and streaming |
Radiometric IR-video recording |
Real-time to built-in RAM, transferable to memory card. |
Non-radiometric IR-video recording |
MPEG-4 to memory card |
Non-radiometric IR-video streaming |
MPEG-4 to PC using USB or WLAN (optional) |
Digital camera |
Built-in digital camera |
3.2 Mpixel, auto focus, and video lamp |
Laser pointer |
Laser |
Activated by dedicated button |
Data communication interfaces |
Interfaces |
USB-mini, USB-A, IrDA, composite video, headset connection |
Power system |
Battery |
Li Ion, 3 hours operating time |
Charging system |
In camera (AC adapter or 12 V from a vehicle) or 2-bay charger |
Power management |
Automatic shutdown and sleep mode (user selectable) |
Environmental |
Operating temperature range |
-15°C to +50°C |
Storage temperature range |
-40°C to +70°C |
Humidity (operating and storage) |
IEC 68-2-30/24 h 95% relative humidity +25°C to +40°C |
Encapsulation |
IP 54 (IEC 60529) |
Shock |
25 g (IEC 60068-2-29) |
Vibration |
2 g (IEC 60068-2-6) |
PHYSICAL CHARACTERISTICS |
Camera weight, incl. lens and battery |
2.18 kg |
Cameras size, incl. lens (L ? W ? H) |
355 ? 144 ? 147 mm |
Tripod mounting |
UNC ?"-20 |