INFRARED CAMERA » FLIR A615

Automation: speed up your design cycle with infrared

      The FLIR A615 camera has features and functions that make it the natural choice for anyone who uses PC software to solve problems and needs 640 X 480 pixel resolution. Among its main features are GigE Vision? and GenICam? compliance, which makes it plug-and-play when used with software packages such as IMAQ Vision and Halcon.

Features
• Affordable
• GigE compliant
• GenICam compliant
• Trigg/synchronization/GPIO
• 16-bit 640 X 480 images @ 50 Hz, signal, temperature linear, and radiometric
• Windowing mode: 640 X 240 @ 100 Hz or 640 X 120 @ 200 Hz
• Compliant with any software that supports GenICam, including National
• Instruments IMAQ Vision and Stemmers Common Vision Blox
• Open and well described TCP/IP protocol for control and set-up

Typical applications:
• High-end infrared machine vision that needs temperature
• measurement
• Slag detection
• Food processing
• Electronics testing
• Power resistor testing
• Automotive
IR Automation in Automobile Industry IR Automation in Electronics
Cars and commercial vehicles, engine manufacturing and subcontractors serving the industry:
• Soldering and welding
• Car seat heating
• Verification of window defrosting
• Heating, air conditioning functions
• Casting of plastic or metallic parts
• Quality checking of laminated parts such as dashboards
• Quality checking of leather upholstery
• Friction control of tires
• Electronics design, PCB and component manufacture and electronics assembly:
• PCB testing, validation and verification
• Fault tracing in board assemblies
• Power electronics design
FLIR ThermoVision A615 Specifications
Imaging Performance
Field of view (FOV)
Minimum focus distance
Focal Length
Spatial resolution
Lens identification
F-number
Thermal sensitivity/ NETD
Image frequency
Focus
25° X 18.8°
0.4m
24.5mm
0.69mrad
Automation
1.0
<0.05°C @ + 30°C/ 50mK
50Hz (100/200 Hz with windowing)
Automatic or manual (built in motor)
Detector data
Detector type
Spectral range
IR resolution
Detector pitch
Detector time constant
Focal Plane Array (FPA), uncooled microbolometer
7.5-13 µm
640 X 480pixels
17µm
Typical 8ms
Measurement
Object temperature range
Accuracy
-20°C to + 150°C     0 to +650°C
±2°C or ±2% of reading
Measurement analysis
Atmosphere transmission Automatic, based on inputs for distance,
correction atmospheric temperature and relative humidity
Optics transmission correction Automatic, based on signals from internal sensors
Emissivity correction Variable from 0.01 to 1.0
Reflected apparent Automatic, based on input of reflected temperature
Reference temperature Manually set or captured from any measurement function
temperature correction
 
External optics/ Automatic, based on input of optics/ window
Measurement corrections Global object parameters
USB
USB Control and image
USB, standard USB 2 HS
USB, connector type USB Mini-B
USB, communication TCP/IP socket-based FLIR proprietary
USB, image streaming 16-bit 640 X 480 pixels @ 25Hz
16-bit 640 X 240 pixels @ 50Hz
16-bit 640 X 120 pixels @ 100Hz
- Signal linear
- Temperature linear
- Radiometric
USB, protocols TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), nPnP
Ethernet
Ethernet Control and image
Ethernet, type Gigabit Ethernet
Ethernet, standard IEEE 802.3
Ethernet, connector type RJ-45
Ethernet, communication TCP/IP socket-based FLIR proprietary and GenICam protocol
Ethernet, image streaming 16-bit 640 X 480 pixels @ 50 Hz
16-bit 640 X 240 pixels @ 100 Hz
16-bit 640 X 120 pixels @ 200 Hz
- Signal linear
- Temperature linear
- Radiometric
GigE Vision and GenICam compatible
Ethernet, protocols TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Digital input/ output
Digital input, purpose Image tag (start/ stop/ general), Input ext. device (programmatically read)
Digital input 2 opto-isolated, 10-30 VDC
Digital output, purpose Output to ext. device (programmatically set)
Digital output 2 opto-isolated, 10-30 VDC, max 100mA
Digital I/O, isolation voltage 500VRMS
Digital I/O, supply voltage 12/24 VDC, max 200 mA
Digital I/O, connector type 6-pole jackable screw terminal
Power system
External power operation 12/24 VDC, 24W absolute max
External power,connector type 2-pole jackable screw terminal
Voltage Allowed range 10-30 VDC
Environmental data
Operating temperature range -15°C to +50°C
Storage temperature range -40°C to +70°C
Humidity (operating and storage) IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C
EMC - EN 61000-6-2:2001 (Immunity)
- EN 61000-6-3:2001 (Emission)
- FCC 47 CFR Part 15 Class B (Emission)
Encapsulation IP 40 (IEC 60529)
Bump 25g (IEC 60068-2-29)
Vibration 2g (IEC 60068-2-6)
Physical data
Weight 0.7kg
Camera size (L x W x H) 216 X 73 X 75mm
Tripod mounting UNC1/4”-20 (on three sides)
Base mounting 2 X M4 thread mounting holes (on three sides)
Housing material Aluminium

©Copyright 2012 - Thermoscan Co., Ltd. - All Rights Reserved.
Thermoscan Co., Ltd. (บริษัท เทอร์โมสแกน จำกัด)
FLIR Authorized Distributor in Thailand
( ตัวแทนจำหน่ายกล้อง FLIR ในประเทศไทย )
731 PM Tower, 5th Floor, Asok Dindaeng Road, Dindaeng, Dindaeng, Bangkok 10400
Tel: (02) 642-9489    Fax: (02) 642-9424
E-mail: tms@thermoscan.co.th